DTC |
Description |
---|---|
P0161 |
Oxy Sensor Heater Downstream Cat bank 2 Drive cycle C:Signal out of range - above maximum. |
P0161 |
Oxy Sensor Heater Downstream Cat bank 2 Drive cycle C:Signal out of range - below minimum. |
1. Open circuit heater - oxygen sensor/3 to oxygen sensor/4.
OPEN_CIRCUIT Check resistance > 1M&! |
2. Open circuit C635/1 (WU) to C642/4 (WU).
OPEN_CIRCUIT Check resistance > 1M&! |
3. Open circuit C573/3 (NK) to C642/3 (NK).
OPEN_CIRCUIT Check resistance > 1M&! |
4. Fuse condition - F2 Engine Compartment Fusebox.
POWER_DISTRIBUTION Check for fuse not correctly inserted, fuse blown, fuse connections loose, damaged or corroded. Certain diagnostics may also perform further checks to try and narrow down the fault. e.g. Check if other circuits fed by the same fuse are also experiencing problems. |
5. Connector(s) C642,ECM C635 (B).
CONNECTOR Check for connector not correctly latched, backed out pins, damaged pins, corroded pins. |